blob: 972bc8cd4384e8d0eab0876f7cdae52537dd3b3a [file] [log] [blame]
Hans Verkuilab15d242018-02-07 09:05:46 -05001/* SPDX-License-Identifier: GPL-2.0-only */
Hans Verkuila56960e2016-06-25 09:43:58 -03002/*
3 * cec - HDMI Consumer Electronics Control support header
4 *
5 * Copyright 2016 Cisco Systems, Inc. and/or its affiliates. All rights reserved.
Hans Verkuila56960e2016-06-25 09:43:58 -03006 */
7
8#ifndef _MEDIA_CEC_H
9#define _MEDIA_CEC_H
10
11#include <linux/poll.h>
12#include <linux/fs.h>
13#include <linux/debugfs.h>
14#include <linux/device.h>
15#include <linux/cdev.h>
16#include <linux/kthread.h>
17#include <linux/timer.h>
18#include <linux/cec-funcs.h>
19#include <media/rc-core.h>
Dariusz Marcinkiewicz32a847f2019-06-20 05:17:18 -040020
Hans Verkuilee0c5032017-08-04 06:41:51 -040021#define CEC_CAP_DEFAULTS (CEC_CAP_LOG_ADDRS | CEC_CAP_TRANSMIT | \
22 CEC_CAP_PASSTHROUGH | CEC_CAP_RC)
23
Hans Verkuila56960e2016-06-25 09:43:58 -030024/**
25 * struct cec_devnode - cec device node
26 * @dev: cec device
27 * @cdev: cec character device
Hans Verkuila56960e2016-06-25 09:43:58 -030028 * @minor: device node minor number
29 * @registered: the device was correctly registered
30 * @unregistered: the device was unregistered
31 * @fhs_lock: lock to control access to the filehandle list
32 * @fhs: the list of open filehandles (cec_fh)
33 *
34 * This structure represents a cec-related device node.
35 *
36 * The @parent is a physical device. It must be set by core or device drivers
37 * before registering the node.
38 */
39struct cec_devnode {
40 /* sysfs */
41 struct device dev;
42 struct cdev cdev;
Hans Verkuila56960e2016-06-25 09:43:58 -030043
44 /* device info */
45 int minor;
46 bool registered;
47 bool unregistered;
Hans Verkuila56960e2016-06-25 09:43:58 -030048 struct list_head fhs;
Hans Verkuil62148f092016-08-02 08:11:00 -030049 struct mutex lock;
Hans Verkuila56960e2016-06-25 09:43:58 -030050};
51
52struct cec_adapter;
53struct cec_data;
Hans Verkuilea5c8ef2017-07-11 03:30:42 -030054struct cec_pin;
Dariusz Marcinkiewicz32a847f2019-06-20 05:17:18 -040055struct cec_notifier;
Hans Verkuila56960e2016-06-25 09:43:58 -030056
57struct cec_data {
58 struct list_head list;
59 struct list_head xfer_list;
60 struct cec_adapter *adap;
61 struct cec_msg msg;
62 struct cec_fh *fh;
63 struct delayed_work work;
64 struct completion c;
65 u8 attempts;
Hans Verkuila56960e2016-06-25 09:43:58 -030066 bool blocking;
67 bool completed;
68};
69
70struct cec_msg_entry {
71 struct list_head list;
72 struct cec_msg msg;
73};
74
Hans Verkuil6b2bbb02017-07-11 03:30:39 -030075struct cec_event_entry {
76 struct list_head list;
77 struct cec_event ev;
78};
79
80#define CEC_NUM_CORE_EVENTS 2
Hans Verkuil4786b0d2018-06-28 07:43:46 -040081#define CEC_NUM_EVENTS CEC_EVENT_PIN_5V_HIGH
Hans Verkuila56960e2016-06-25 09:43:58 -030082
83struct cec_fh {
84 struct list_head list;
85 struct list_head xfer_list;
86 struct cec_adapter *adap;
87 u8 mode_initiator;
88 u8 mode_follower;
89
90 /* Events */
91 wait_queue_head_t wait;
Hans Verkuila56960e2016-06-25 09:43:58 -030092 struct mutex lock;
Hans Verkuil6b2bbb02017-07-11 03:30:39 -030093 struct list_head events[CEC_NUM_EVENTS]; /* queued events */
Hans Verkuil6ec1cbf2018-03-06 16:20:00 -050094 u16 queued_events[CEC_NUM_EVENTS];
Hans Verkuil6b2bbb02017-07-11 03:30:39 -030095 unsigned int total_queued_events;
96 struct cec_event_entry core_events[CEC_NUM_CORE_EVENTS];
Hans Verkuila56960e2016-06-25 09:43:58 -030097 struct list_head msgs; /* queued messages */
98 unsigned int queued_msgs;
99};
100
101#define CEC_SIGNAL_FREE_TIME_RETRY 3
102#define CEC_SIGNAL_FREE_TIME_NEW_INITIATOR 5
103#define CEC_SIGNAL_FREE_TIME_NEXT_XFER 7
104
105/* The nominal data bit period is 2.4 ms */
106#define CEC_FREE_TIME_TO_USEC(ft) ((ft) * 2400)
107
108struct cec_adap_ops {
109 /* Low-level callbacks */
110 int (*adap_enable)(struct cec_adapter *adap, bool enable);
111 int (*adap_monitor_all_enable)(struct cec_adapter *adap, bool enable);
Hans Verkuil48ea2e92017-11-05 07:36:36 -0500112 int (*adap_monitor_pin_enable)(struct cec_adapter *adap, bool enable);
Hans Verkuila56960e2016-06-25 09:43:58 -0300113 int (*adap_log_addr)(struct cec_adapter *adap, u8 logical_addr);
114 int (*adap_transmit)(struct cec_adapter *adap, u8 attempts,
115 u32 signal_free_time, struct cec_msg *msg);
116 void (*adap_status)(struct cec_adapter *adap, struct seq_file *file);
Hans Verkuile6259b52017-07-11 03:30:36 -0300117 void (*adap_free)(struct cec_adapter *adap);
Hans Verkuila56960e2016-06-25 09:43:58 -0300118
Hans Verkuil9ca400c2017-10-31 09:55:09 -0400119 /* Error injection callbacks */
120 int (*error_inj_show)(struct cec_adapter *adap, struct seq_file *sf);
121 bool (*error_inj_parse_line)(struct cec_adapter *adap, char *line);
122
Hans Verkuila56960e2016-06-25 09:43:58 -0300123 /* High-level CEC message callback */
124 int (*received)(struct cec_adapter *adap, struct cec_msg *msg);
125};
126
127/*
128 * The minimum message length you can receive (excepting poll messages) is 2.
129 * With a transfer rate of at most 36 bytes per second this makes 18 messages
130 * per second worst case.
131 *
Hans Verkuil11065f82016-07-17 11:40:05 -0300132 * We queue at most 3 seconds worth of received messages. The CEC specification
133 * requires that messages are replied to within a second, so 3 seconds should
134 * give more than enough margin. Since most messages are actually more than 2
135 * bytes, this is in practice a lot more than 3 seconds.
Hans Verkuila56960e2016-06-25 09:43:58 -0300136 */
Hans Verkuil11065f82016-07-17 11:40:05 -0300137#define CEC_MAX_MSG_RX_QUEUE_SZ (18 * 3)
138
139/*
140 * The transmit queue is limited to 1 second worth of messages (worst case).
141 * Messages can be transmitted by userspace and kernel space. But for both it
142 * makes no sense to have a lot of messages queued up. One second seems
143 * reasonable.
144 */
145#define CEC_MAX_MSG_TX_QUEUE_SZ (18 * 1)
Hans Verkuila56960e2016-06-25 09:43:58 -0300146
147struct cec_adapter {
148 struct module *owner;
149 char name[32];
150 struct cec_devnode devnode;
151 struct mutex lock;
152 struct rc_dev *rc;
153
154 struct list_head transmit_queue;
Hans Verkuil11065f82016-07-17 11:40:05 -0300155 unsigned int transmit_queue_sz;
Hans Verkuila56960e2016-06-25 09:43:58 -0300156 struct list_head wait_queue;
157 struct cec_data *transmitting;
Hans Verkuil32804fc2018-10-19 03:55:34 -0400158 bool transmit_in_progress;
Hans Verkuila56960e2016-06-25 09:43:58 -0300159
160 struct task_struct *kthread_config;
161 struct completion config_completion;
162
163 struct task_struct *kthread;
164 wait_queue_head_t kthread_waitq;
165 wait_queue_head_t waitq;
166
167 const struct cec_adap_ops *ops;
168 void *priv;
169 u32 capabilities;
170 u8 available_log_addrs;
171
172 u16 phys_addr;
Hans Verkuilf902c1e2017-06-07 11:46:12 -0300173 bool needs_hpd;
Hans Verkuila56960e2016-06-25 09:43:58 -0300174 bool is_configuring;
175 bool is_configured;
Hans Verkuil28e11b12017-08-20 06:53:10 -0400176 bool cec_pin_is_high;
Hans Verkuil7d867a12018-10-05 08:00:21 -0400177 u8 last_initiator;
Hans Verkuila56960e2016-06-25 09:43:58 -0300178 u32 monitor_all_cnt;
Hans Verkuilb8d62f52017-07-11 03:30:41 -0300179 u32 monitor_pin_cnt;
Hans Verkuila56960e2016-06-25 09:43:58 -0300180 u32 follower_cnt;
181 struct cec_fh *cec_follower;
182 struct cec_fh *cec_initiator;
183 bool passthrough;
184 struct cec_log_addrs log_addrs;
Dariusz Marcinkiewicz32a847f2019-06-20 05:17:18 -0400185 struct cec_connector_info conn_info;
Hans Verkuila56960e2016-06-25 09:43:58 -0300186
Hans Verkuilbb789e02017-07-11 03:30:34 -0300187 u32 tx_timeouts;
188
Hans Verkuile94c3282017-05-28 05:58:04 -0300189#ifdef CONFIG_CEC_NOTIFIER
Hans Verkuile3a93ad2016-12-13 12:15:57 -0200190 struct cec_notifier *notifier;
191#endif
Hans Verkuilea5c8ef2017-07-11 03:30:42 -0300192#ifdef CONFIG_CEC_PIN
193 struct cec_pin *pin;
194#endif
Hans Verkuile3a93ad2016-12-13 12:15:57 -0200195
Hans Verkuila56960e2016-06-25 09:43:58 -0300196 struct dentry *cec_dir;
197 struct dentry *status_file;
Hans Verkuil9ca400c2017-10-31 09:55:09 -0400198 struct dentry *error_inj_file;
Hans Verkuila56960e2016-06-25 09:43:58 -0300199
200 u16 phys_addrs[15];
201 u32 sequence;
202
Hans Verkuila56960e2016-06-25 09:43:58 -0300203 char input_phys[32];
Hans Verkuila56960e2016-06-25 09:43:58 -0300204};
205
Jose Abreu0b0b97d2017-03-24 13:47:52 -0300206static inline void *cec_get_drvdata(const struct cec_adapter *adap)
207{
208 return adap->priv;
209}
210
Hans Verkuila56960e2016-06-25 09:43:58 -0300211static inline bool cec_has_log_addr(const struct cec_adapter *adap, u8 log_addr)
212{
213 return adap->log_addrs.log_addr_mask & (1 << log_addr);
214}
215
216static inline bool cec_is_sink(const struct cec_adapter *adap)
217{
218 return adap->phys_addr == 0;
219}
220
Hans Verkuilc8959a32017-11-22 04:12:39 -0500221/**
222 * cec_is_registered() - is the CEC adapter registered?
223 *
224 * @adap: the CEC adapter, may be NULL.
225 *
226 * Return: true if the adapter is registered, false otherwise.
227 */
228static inline bool cec_is_registered(const struct cec_adapter *adap)
229{
230 return adap && adap->devnode.registered;
231}
232
Hans Verkuilee7e98712017-04-17 07:54:37 -0300233#define cec_phys_addr_exp(pa) \
234 ((pa) >> 12), ((pa) >> 8) & 0xf, ((pa) >> 4) & 0xf, (pa) & 0xf
235
Hans Verkuil23111ec2017-06-07 11:46:08 -0300236struct edid;
Dariusz Marcinkiewicz32a847f2019-06-20 05:17:18 -0400237struct drm_connector;
Hans Verkuil23111ec2017-06-07 11:46:08 -0300238
Hans Verkuilf9f314f2017-06-08 15:37:44 -0300239#if IS_REACHABLE(CONFIG_CEC_CORE)
Hans Verkuila56960e2016-06-25 09:43:58 -0300240struct cec_adapter *cec_allocate_adapter(const struct cec_adap_ops *ops,
Hans Verkuilf51e8082016-11-25 06:23:34 -0200241 void *priv, const char *name, u32 caps, u8 available_las);
242int cec_register_adapter(struct cec_adapter *adap, struct device *parent);
Hans Verkuila56960e2016-06-25 09:43:58 -0300243void cec_unregister_adapter(struct cec_adapter *adap);
244void cec_delete_adapter(struct cec_adapter *adap);
245
246int cec_s_log_addrs(struct cec_adapter *adap, struct cec_log_addrs *log_addrs,
247 bool block);
248void cec_s_phys_addr(struct cec_adapter *adap, u16 phys_addr,
249 bool block);
Hans Verkuil23111ec2017-06-07 11:46:08 -0300250void cec_s_phys_addr_from_edid(struct cec_adapter *adap,
251 const struct edid *edid);
Dariusz Marcinkiewicz32a847f2019-06-20 05:17:18 -0400252void cec_s_conn_info(struct cec_adapter *adap,
253 const struct cec_connector_info *conn_info);
Hans Verkuila56960e2016-06-25 09:43:58 -0300254int cec_transmit_msg(struct cec_adapter *adap, struct cec_msg *msg,
255 bool block);
256
257/* Called by the adapter */
Hans Verkuil0861ad12017-07-11 03:30:35 -0300258void cec_transmit_done_ts(struct cec_adapter *adap, u8 status,
259 u8 arb_lost_cnt, u8 nack_cnt, u8 low_drive_cnt,
260 u8 error_cnt, ktime_t ts);
261
262static inline void cec_transmit_done(struct cec_adapter *adap, u8 status,
263 u8 arb_lost_cnt, u8 nack_cnt,
264 u8 low_drive_cnt, u8 error_cnt)
265{
266 cec_transmit_done_ts(adap, status, arb_lost_cnt, nack_cnt,
267 low_drive_cnt, error_cnt, ktime_get());
268}
Hans Verkuilc94cdc12017-06-07 11:46:10 -0300269/*
270 * Simplified version of cec_transmit_done for hardware that doesn't retry
271 * failed transmits. So this is always just one attempt in which case
272 * the status is sufficient.
273 */
Hans Verkuil0861ad12017-07-11 03:30:35 -0300274void cec_transmit_attempt_done_ts(struct cec_adapter *adap,
275 u8 status, ktime_t ts);
276
277static inline void cec_transmit_attempt_done(struct cec_adapter *adap,
278 u8 status)
279{
280 cec_transmit_attempt_done_ts(adap, status, ktime_get());
281}
282
283void cec_received_msg_ts(struct cec_adapter *adap,
284 struct cec_msg *msg, ktime_t ts);
285
286static inline void cec_received_msg(struct cec_adapter *adap,
287 struct cec_msg *msg)
288{
289 cec_received_msg_ts(adap, msg, ktime_get());
290}
Hans Verkuila56960e2016-06-25 09:43:58 -0300291
Hans Verkuilee7e98712017-04-17 07:54:37 -0300292/**
Hans Verkuil9a6b2a82017-08-15 15:26:25 -0400293 * cec_queue_pin_cec_event() - queue a CEC pin event with a given timestamp.
Hans Verkuilb8d62f52017-07-11 03:30:41 -0300294 *
295 * @adap: pointer to the cec adapter
Hans Verkuil9a6b2a82017-08-15 15:26:25 -0400296 * @is_high: when true the CEC pin is high, otherwise it is low
Hans Verkuil6ec1cbf2018-03-06 16:20:00 -0500297 * @dropped_events: when true some events were dropped
Hans Verkuilb8d62f52017-07-11 03:30:41 -0300298 * @ts: the timestamp for this event
299 *
300 */
Hans Verkuil6ec1cbf2018-03-06 16:20:00 -0500301void cec_queue_pin_cec_event(struct cec_adapter *adap, bool is_high,
302 bool dropped_events, ktime_t ts);
Hans Verkuilb8d62f52017-07-11 03:30:41 -0300303
304/**
Hans Verkuil333ef6b2017-08-15 10:07:25 -0400305 * cec_queue_pin_hpd_event() - queue a pin event with a given timestamp.
306 *
307 * @adap: pointer to the cec adapter
308 * @is_high: when true the HPD pin is high, otherwise it is low
309 * @ts: the timestamp for this event
310 *
311 */
312void cec_queue_pin_hpd_event(struct cec_adapter *adap, bool is_high, ktime_t ts);
313
314/**
Hans Verkuil4786b0d2018-06-28 07:43:46 -0400315 * cec_queue_pin_5v_event() - queue a pin event with a given timestamp.
316 *
317 * @adap: pointer to the cec adapter
318 * @is_high: when true the 5V pin is high, otherwise it is low
319 * @ts: the timestamp for this event
320 *
321 */
322void cec_queue_pin_5v_event(struct cec_adapter *adap, bool is_high, ktime_t ts);
323
324/**
Hans Verkuilee7e98712017-04-17 07:54:37 -0300325 * cec_get_edid_phys_addr() - find and return the physical address
326 *
327 * @edid: pointer to the EDID data
328 * @size: size in bytes of the EDID data
329 * @offset: If not %NULL then the location of the physical address
330 * bytes in the EDID will be returned here. This is set to 0
331 * if there is no physical address found.
332 *
333 * Return: the physical address or CEC_PHYS_ADDR_INVALID if there is none.
334 */
335u16 cec_get_edid_phys_addr(const u8 *edid, unsigned int size,
336 unsigned int *offset);
337
Dariusz Marcinkiewicz32a847f2019-06-20 05:17:18 -0400338void cec_fill_conn_info_from_drm(struct cec_connector_info *conn_info,
339 const struct drm_connector *connector);
340
Hans Verkuila56960e2016-06-25 09:43:58 -0300341#else
342
Hans Verkuilf51e8082016-11-25 06:23:34 -0200343static inline int cec_register_adapter(struct cec_adapter *adap,
344 struct device *parent)
Hans Verkuila56960e2016-06-25 09:43:58 -0300345{
346 return 0;
347}
348
349static inline void cec_unregister_adapter(struct cec_adapter *adap)
350{
351}
352
353static inline void cec_delete_adapter(struct cec_adapter *adap)
354{
355}
356
357static inline void cec_s_phys_addr(struct cec_adapter *adap, u16 phys_addr,
358 bool block)
359{
360}
361
Hans Verkuil23111ec2017-06-07 11:46:08 -0300362static inline void cec_s_phys_addr_from_edid(struct cec_adapter *adap,
363 const struct edid *edid)
364{
365}
366
Hans Verkuilee7e98712017-04-17 07:54:37 -0300367static inline u16 cec_get_edid_phys_addr(const u8 *edid, unsigned int size,
368 unsigned int *offset)
369{
370 if (offset)
371 *offset = 0;
372 return CEC_PHYS_ADDR_INVALID;
373}
374
Dariusz Marcinkiewicz32a847f2019-06-20 05:17:18 -0400375static inline void cec_s_conn_info(struct cec_adapter *adap,
376 const struct cec_connector_info *conn_info)
377{
378}
379
380static inline void
381cec_fill_conn_info_from_drm(struct cec_connector_info *conn_info,
382 const struct drm_connector *connector)
383{
384 memset(conn_info, 0, sizeof(*conn_info));
385}
386
387#endif
388
Hans Verkuil13532782017-06-07 11:46:09 -0300389/**
390 * cec_phys_addr_invalidate() - set the physical address to INVALID
391 *
392 * @adap: the CEC adapter
393 *
394 * This is a simple helper function to invalidate the physical
395 * address.
396 */
397static inline void cec_phys_addr_invalidate(struct cec_adapter *adap)
398{
399 cec_s_phys_addr(adap, CEC_PHYS_ADDR_INVALID, false);
400}
401
Hans Verkuilb915bf572018-09-13 03:25:59 -0400402/**
403 * cec_get_edid_spa_location() - find location of the Source Physical Address
404 *
405 * @edid: the EDID
406 * @size: the size of the EDID
407 *
408 * This EDID is expected to be a CEA-861 compliant, which means that there are
409 * at least two blocks and one or more of the extensions blocks are CEA-861
410 * blocks.
411 *
412 * The returned location is guaranteed to be <= size-2.
413 *
414 * This is an inline function since it is used by both CEC and V4L2.
415 * Ideally this would go in a module shared by both, but it is overkill to do
416 * that for just a single function.
417 */
418static inline unsigned int cec_get_edid_spa_location(const u8 *edid,
419 unsigned int size)
420{
421 unsigned int blocks = size / 128;
422 unsigned int block;
423 u8 d;
424
425 /* Sanity check: at least 2 blocks and a multiple of the block size */
426 if (blocks < 2 || size % 128)
427 return 0;
428
429 /*
430 * If there are fewer extension blocks than the size, then update
431 * 'blocks'. It is allowed to have more extension blocks than the size,
432 * since some hardware can only read e.g. 256 bytes of the EDID, even
433 * though more blocks are present. The first CEA-861 extension block
434 * should normally be in block 1 anyway.
435 */
436 if (edid[0x7e] + 1 < blocks)
437 blocks = edid[0x7e] + 1;
438
439 for (block = 1; block < blocks; block++) {
440 unsigned int offset = block * 128;
441
442 /* Skip any non-CEA-861 extension blocks */
443 if (edid[offset] != 0x02 || edid[offset + 1] != 0x03)
444 continue;
445
446 /* search Vendor Specific Data Block (tag 3) */
447 d = edid[offset + 2] & 0x7f;
448 /* Check if there are Data Blocks */
449 if (d <= 4)
450 continue;
451 if (d > 4) {
452 unsigned int i = offset + 4;
453 unsigned int end = offset + d;
454
455 /* Note: 'end' is always < 'size' */
456 do {
457 u8 tag = edid[i] >> 5;
458 u8 len = edid[i] & 0x1f;
459
460 if (tag == 3 && len >= 5 && i + len <= end &&
461 edid[i + 1] == 0x03 &&
462 edid[i + 2] == 0x0c &&
463 edid[i + 3] == 0x00)
464 return i + 4;
465 i += len + 1;
466 } while (i < end);
467 }
468 }
469 return 0;
470}
471
Hans Verkuila56960e2016-06-25 09:43:58 -0300472#endif /* _MEDIA_CEC_H */