clk: si5351: Rename internal plls to avoid name collisions
This drivers probe fails due to a clock name collision if a clock named
'plla' or 'pllb' is already registered when registering this drivers
internal plls.
Fix it by renaming internal plls to avoid name collisions.
Cc: Sebastian Hesselbarth <sebastian.hesselbarth@gmail.com>
Cc: Rabeeh Khoury <rabeeh@solid-run.com>
Signed-off-by: Sergej Sawazki <sergej@taudac.com>
Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>
diff --git a/drivers/clk/clk-si5351.c b/drivers/clk/clk-si5351.c
index 79b770f..841d9fe 100644
--- a/drivers/clk/clk-si5351.c
+++ b/drivers/clk/clk-si5351.c
@@ -72,7 +72,7 @@ static const char * const si5351_input_names[] = {
"xtal", "clkin"
};
static const char * const si5351_pll_names[] = {
- "plla", "pllb", "vxco"
+ "si5351_plla", "si5351_pllb", "si5351_vxco"
};
static const char * const si5351_msynth_names[] = {
"ms0", "ms1", "ms2", "ms3", "ms4", "ms5", "ms6", "ms7"