net: dsa: mv88e6xxx: Add 6390 family PCS registers to ethtool -d
The mv88e6390 has upto 8 sets of PCS registers, depending on how ports
9 and 10 are configured. The can be spread over 8 ports. If a port has
a PCS register set, return it along with the port registers. The
register space is sparse, so hard code a list of registers which will
be returned. It can later be extended, if needed, by append to the end
of the list.
Signed-off-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
diff --git a/drivers/net/dsa/mv88e6xxx/chip.c b/drivers/net/dsa/mv88e6xxx/chip.c
index cb284eb..4ec09cc 100644
--- a/drivers/net/dsa/mv88e6xxx/chip.c
+++ b/drivers/net/dsa/mv88e6xxx/chip.c
@@ -3861,6 +3861,8 @@ static const struct mv88e6xxx_ops mv88e6190_ops = {
.serdes_irq_status = mv88e6390_serdes_irq_status,
.serdes_get_strings = mv88e6390_serdes_get_strings,
.serdes_get_stats = mv88e6390_serdes_get_stats,
+ .serdes_get_regs_len = mv88e6390_serdes_get_regs_len,
+ .serdes_get_regs = mv88e6390_serdes_get_regs,
.phylink_validate = mv88e6390_phylink_validate,
.gpio_ops = &mv88e6352_gpio_ops,
.phylink_validate = mv88e6390_phylink_validate,
@@ -3915,6 +3917,8 @@ static const struct mv88e6xxx_ops mv88e6190x_ops = {
.serdes_irq_status = mv88e6390_serdes_irq_status,
.serdes_get_strings = mv88e6390_serdes_get_strings,
.serdes_get_stats = mv88e6390_serdes_get_stats,
+ .serdes_get_regs_len = mv88e6390_serdes_get_regs_len,
+ .serdes_get_regs = mv88e6390_serdes_get_regs,
.phylink_validate = mv88e6390_phylink_validate,
.gpio_ops = &mv88e6352_gpio_ops,
.phylink_validate = mv88e6390x_phylink_validate,
@@ -3968,6 +3972,8 @@ static const struct mv88e6xxx_ops mv88e6191_ops = {
.serdes_irq_status = mv88e6390_serdes_irq_status,
.serdes_get_strings = mv88e6390_serdes_get_strings,
.serdes_get_stats = mv88e6390_serdes_get_stats,
+ .serdes_get_regs_len = mv88e6390_serdes_get_regs_len,
+ .serdes_get_regs = mv88e6390_serdes_get_regs,
.phylink_validate = mv88e6390_phylink_validate,
.avb_ops = &mv88e6390_avb_ops,
.ptp_ops = &mv88e6352_ptp_ops,
@@ -4119,6 +4125,8 @@ static const struct mv88e6xxx_ops mv88e6290_ops = {
.serdes_irq_status = mv88e6390_serdes_irq_status,
.serdes_get_strings = mv88e6390_serdes_get_strings,
.serdes_get_stats = mv88e6390_serdes_get_stats,
+ .serdes_get_regs_len = mv88e6390_serdes_get_regs_len,
+ .serdes_get_regs = mv88e6390_serdes_get_regs,
.phylink_validate = mv88e6390_phylink_validate,
.gpio_ops = &mv88e6352_gpio_ops,
.avb_ops = &mv88e6390_avb_ops,
@@ -4464,6 +4472,8 @@ static const struct mv88e6xxx_ops mv88e6390_ops = {
.serdes_get_sset_count = mv88e6390_serdes_get_sset_count,
.serdes_get_strings = mv88e6390_serdes_get_strings,
.serdes_get_stats = mv88e6390_serdes_get_stats,
+ .serdes_get_regs_len = mv88e6390_serdes_get_regs_len,
+ .serdes_get_regs = mv88e6390_serdes_get_regs,
.phylink_validate = mv88e6390_phylink_validate,
};
@@ -4519,6 +4529,8 @@ static const struct mv88e6xxx_ops mv88e6390x_ops = {
.serdes_get_sset_count = mv88e6390_serdes_get_sset_count,
.serdes_get_strings = mv88e6390_serdes_get_strings,
.serdes_get_stats = mv88e6390_serdes_get_stats,
+ .serdes_get_regs_len = mv88e6390_serdes_get_regs_len,
+ .serdes_get_regs = mv88e6390_serdes_get_regs,
.gpio_ops = &mv88e6352_gpio_ops,
.avb_ops = &mv88e6390_avb_ops,
.ptp_ops = &mv88e6352_ptp_ops,