powerpc: fix double syscall restarts

Make sigreturn zero regs->trap, make do_signal() do the same on all
paths.  As it is, signal interrupting e.g. read() from fd 512 (==
ERESTARTSYS) with another signal getting unblocked when the first
handler finishes will lead to restart one insn earlier than it ought
to.  Same for multiple signals with in-kernel handlers interrupting
that sucker at the same time.  Same for multiple signals of any kind
interrupting that sucker on 64bit...

Signed-off-by: Al Viro <viro@zeniv.linux.org.uk>
Acked-by: Paul Mackerras <paulus@samba.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
diff --git a/arch/powerpc/kernel/signal_64.c b/arch/powerpc/kernel/signal_64.c
index 2fe6fc6..27c4a45 100644
--- a/arch/powerpc/kernel/signal_64.c
+++ b/arch/powerpc/kernel/signal_64.c
@@ -178,7 +178,7 @@
 	err |= __get_user(regs->xer, &sc->gp_regs[PT_XER]);
 	err |= __get_user(regs->ccr, &sc->gp_regs[PT_CCR]);
 	/* skip SOFTE */
-	err |= __get_user(regs->trap, &sc->gp_regs[PT_TRAP]);
+	regs->trap = 0;
 	err |= __get_user(regs->dar, &sc->gp_regs[PT_DAR]);
 	err |= __get_user(regs->dsisr, &sc->gp_regs[PT_DSISR]);