drop_monitor: Filter control packets in drop monitor
Previously, devlink called into drop monitor in order to report hardware
originated drops / exceptions. devlink intentionally filtered control
packets and did not pass them to drop monitor as they were not dropped
by the underlying hardware.
Now drop monitor registers its probe on a generic 'devlink_trap_report'
tracepoint and should therefore perform this filtering itself instead of
having devlink do that.
Add the trap type as metadata and have drop monitor ignore control
packets.
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Reviewed-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
diff --git a/include/net/devlink.h b/include/net/devlink.h
index 1014294b..1c286e9 100644
--- a/include/net/devlink.h
+++ b/include/net/devlink.h
@@ -630,12 +630,14 @@ struct devlink_health_reporter_ops {
* @trap_group_name: Trap group name.
* @input_dev: Input netdevice.
* @fa_cookie: Flow action user cookie.
+ * @trap_type: Trap type.
*/
struct devlink_trap_metadata {
const char *trap_name;
const char *trap_group_name;
struct net_device *input_dev;
const struct flow_action_cookie *fa_cookie;
+ enum devlink_trap_type trap_type;
};
/**