md/raid5: If there is a spare and a want_replacement device, start replacement.

When attempting to add a spare to a RAID[456] array, also consider
adding it as a replacement for a want_replacement device.

This requires that common md code attempt hot_add even when the array
is not formally degraded.

Reviewed-by: Dan Williams <dan.j.williams@intel.com>
Signed-off-by: NeilBrown <neilb@suse.de>
diff --git a/drivers/md/md.c b/drivers/md/md.c
index be569eb..1c1c562 100644
--- a/drivers/md/md.c
+++ b/drivers/md/md.c
@@ -7399,23 +7399,21 @@
 			}
 		}
 
-	if (mddev->degraded) {
-		list_for_each_entry(rdev, &mddev->disks, same_set) {
-			if (rdev->raid_disk >= 0 &&
-			    !test_bit(In_sync, &rdev->flags) &&
-			    !test_bit(Faulty, &rdev->flags))
+	list_for_each_entry(rdev, &mddev->disks, same_set) {
+		if (rdev->raid_disk >= 0 &&
+		    !test_bit(In_sync, &rdev->flags) &&
+		    !test_bit(Faulty, &rdev->flags))
+			spares++;
+		if (rdev->raid_disk < 0
+		    && !test_bit(Faulty, &rdev->flags)) {
+			rdev->recovery_offset = 0;
+			if (mddev->pers->
+			    hot_add_disk(mddev, rdev) == 0) {
+				if (sysfs_link_rdev(mddev, rdev))
+					/* failure here is OK */;
 				spares++;
-			if (rdev->raid_disk < 0
-			    && !test_bit(Faulty, &rdev->flags)) {
-				rdev->recovery_offset = 0;
-				if (mddev->pers->
-				    hot_add_disk(mddev, rdev) == 0) {
-					if (sysfs_link_rdev(mddev, rdev))
-						/* failure here is OK */;
-					spares++;
-					md_new_event(mddev);
-					set_bit(MD_CHANGE_DEVS, &mddev->flags);
-				}
+				md_new_event(mddev);
+				set_bit(MD_CHANGE_DEVS, &mddev->flags);
 			}
 		}
 	}