s390/idle: fix accounting with machine checks

When a machine check interrupt is triggered during idle, the code
is using the async timer/clock for idle time calculation. It should use
the machine check enter timer/clock which is passed to the macro.

Fixes: 0b0ed657fe00 ("s390: remove critical section cleanup from entry.S")
Cc: <stable@vger.kernel.org> # 5.8
Reviewed-by: Heiko Carstens <hca@linux.ibm.com>
Signed-off-by: Sven Schnelle <svens@linux.ibm.com>
Signed-off-by: Heiko Carstens <hca@linux.ibm.com>