clk: tegra: Fix pllx dyn step calculation
The logic for calculating the input rate used when figuring out the
proper dynamic steps for pllx was incorrect. It is supposed to be
calculated using parent_rate / m but it was just using the parent rate
directly, therefore using the wrong step values.
Signed-off-by: Rhyland Klein <rklein@nvidia.com>
Signed-off-by: Thierry Reding <treding@nvidia.com>
diff --git a/drivers/clk/tegra/clk-tegra210.c b/drivers/clk/tegra/clk-tegra210.c
index caae0dc..ffcb86a 100644
--- a/drivers/clk/tegra/clk-tegra210.c
+++ b/drivers/clk/tegra/clk-tegra210.c
@@ -780,13 +780,13 @@
{
unsigned long input_rate;
- if (!IS_ERR_OR_NULL(hw->clk)) {
+ /* cf rate */
+ if (!IS_ERR_OR_NULL(hw->clk))
input_rate = clk_hw_get_rate(clk_hw_get_parent(hw));
- /* cf rate */
- input_rate /= tegra_pll_get_fixed_mdiv(hw, input_rate);
- } else {
+ else
input_rate = 38400000;
- }
+
+ input_rate /= tegra_pll_get_fixed_mdiv(hw, input_rate);
switch (input_rate) {
case 12000000: