commit | 92e7407ab1bc5024eb467d5788aace0ceff78a9d | [log] [tgz] |
---|---|---|
author | Jean-Baptiste Maneyrol <jmaneyrol@invensense.com> | Wed Feb 19 15:39:53 2020 +0100 |
committer | Jonathan Cameron <Jonathan.Cameron@huawei.com> | Sun Mar 08 17:28:38 2020 +0000 |
tree | 86ec9935c2fc9ac09acd29bc08ca3913553493a1 | |
parent | 398da9942359efad600b9efb33e6573fedc9276d [diff] |
iio: imu: inv_mpu6050: rewrite power and engine management Rewrite clock management to use automatic clock switching present since MPU6500. Sensors engine management can now turn on or off a batch of sensors which simplifies usage a lot. Temperature sensor is now turned on/off depending on usage. Signed-off-by: Jean-Baptiste Maneyrol <jmaneyrol@invensense.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>