ide: WIN_* -> ATA_CMD_*
* Use ATA_CMD_* defines instead of WIN_* ones.
While at it:
* EXABYTE_ENABLE_NEXT -> ATA_EXABYTE_ENABLE_NEST
* SETFEATURES_{EN,DIS}_WCACHE -> SETFEATURES_WC_{ON,OFF}
* SETFEATURES_{EN,DIS}_AAM -> SETFEATURES_AAM_{ON,OFF}
* SMART_* -> ATA_SMART_*
* Remove stale comment from ide-proc.c.
Partially based on earlier work by Chris Wedgwood.
Acked-by: Chris Wedgwood <cw@f00f.org>
Signed-off-by: Bartlomiej Zolnierkiewicz <bzolnier@gmail.com>
diff --git a/drivers/ide/ide-iops.c b/drivers/ide/ide-iops.c
index 95495e4..21647a2 100644
--- a/drivers/ide/ide-iops.c
+++ b/drivers/ide/ide-iops.c
@@ -418,7 +418,7 @@
* ide_fixstring() cleans up and (optionally) byte-swaps a text string,
* removing leading/trailing blanks and compressing internal blanks.
* It is primarily used to tidy up the model name/number fields as
- * returned by the WIN_[P]IDENTIFY commands.
+ * returned by the ATA_CMD_ID_ATA[PI] commands.
*/
void ide_fixstring (u8 *s, const int bytecount, const int byteswap)
@@ -675,7 +675,7 @@
SELECT_MASK(drive, 1);
tp_ops->set_irq(hwif, 0);
msleep(50);
- tp_ops->exec_command(hwif, WIN_IDENTIFY);
+ tp_ops->exec_command(hwif, ATA_CMD_ID_ATA);
timeout = jiffies + WAIT_WORSTCASE;
do {
if (time_after(jiffies, timeout)) {
@@ -770,7 +770,7 @@
tp_ops->tf_load(drive, &task);
- tp_ops->exec_command(hwif, WIN_SETFEATURES);
+ tp_ops->exec_command(hwif, ATA_CMD_SET_FEATURES);
if (drive->quirk_list == 2)
tp_ops->set_irq(hwif, 1);
@@ -890,7 +890,7 @@
unsigned long flags;
spin_lock_irqsave(&ide_lock, flags);
- hwif->tp_ops->exec_command(hwif, WIN_PACKETCMD);
+ hwif->tp_ops->exec_command(hwif, ATA_CMD_PACKET);
ndelay(400);
spin_unlock_irqrestore(&ide_lock, flags);
}
@@ -1100,7 +1100,7 @@
pre_reset(drive);
SELECT_DRIVE(drive);
udelay (20);
- tp_ops->exec_command(hwif, WIN_SRST);
+ tp_ops->exec_command(hwif, ATA_CMD_DEV_RESET);
ndelay(400);
hwgroup->poll_timeout = jiffies + WAIT_WORSTCASE;
hwgroup->polling = 1;