ARM: dts: meson8: Fix the UART device-tree schema validation
[ Upstream commit 57007bfb5469ba31cacf69d52195e8b75f43e32d ]
The dt-bindings for the UART controller only allow the following values
for Meson8 SoCs:
- "amlogic,meson8-uart", "amlogic,meson-ao-uart"
- "amlogic,meson8-uart"
Use the correct fallback compatible string "amlogic,meson-ao-uart" for
AO UART. Drop the "amlogic,meson-uart" compatible string from the EE
domain UART controllers.
Also update the order of the clocks to match the order defined in the
yaml schema.
Fixes: 6ca77502050eff ("ARM: dts: meson8: use stable UART bindings with correct gate clock")
Signed-off-by: Martin Blumenstingl <martin.blumenstingl@googlemail.com>
Signed-off-by: Neil Armstrong <narmstrong@baylibre.com>
Link: https://lore.kernel.org/r/20211227180026.4068352-3-martin.blumenstingl@googlemail.com
Signed-off-by: Sasha Levin <sashal@kernel.org>
diff --git a/arch/arm/boot/dts/meson8.dtsi b/arch/arm/boot/dts/meson8.dtsi
index 740a6c8..0853311 100644
--- a/arch/arm/boot/dts/meson8.dtsi
+++ b/arch/arm/boot/dts/meson8.dtsi
@@ -598,27 +598,27 @@ &timer_abcde {
};
&uart_AO {
- compatible = "amlogic,meson8-uart", "amlogic,meson-uart";
- clocks = <&clkc CLKID_CLK81>, <&xtal>, <&clkc CLKID_CLK81>;
- clock-names = "baud", "xtal", "pclk";
+ compatible = "amlogic,meson8-uart", "amlogic,meson-ao-uart";
+ clocks = <&xtal>, <&clkc CLKID_CLK81>, <&clkc CLKID_CLK81>;
+ clock-names = "xtal", "pclk", "baud";
};
&uart_A {
- compatible = "amlogic,meson8-uart", "amlogic,meson-uart";
- clocks = <&clkc CLKID_CLK81>, <&xtal>, <&clkc CLKID_UART0>;
- clock-names = "baud", "xtal", "pclk";
+ compatible = "amlogic,meson8-uart";
+ clocks = <&xtal>, <&clkc CLKID_UART0>, <&clkc CLKID_CLK81>;
+ clock-names = "xtal", "pclk", "baud";
};
&uart_B {
- compatible = "amlogic,meson8-uart", "amlogic,meson-uart";
- clocks = <&clkc CLKID_CLK81>, <&xtal>, <&clkc CLKID_UART1>;
- clock-names = "baud", "xtal", "pclk";
+ compatible = "amlogic,meson8-uart";
+ clocks = <&xtal>, <&clkc CLKID_UART0>, <&clkc CLKID_CLK81>;
+ clock-names = "xtal", "pclk", "baud";
};
&uart_C {
- compatible = "amlogic,meson8-uart", "amlogic,meson-uart";
- clocks = <&clkc CLKID_CLK81>, <&xtal>, <&clkc CLKID_UART2>;
- clock-names = "baud", "xtal", "pclk";
+ compatible = "amlogic,meson8-uart";
+ clocks = <&xtal>, <&clkc CLKID_UART0>, <&clkc CLKID_CLK81>;
+ clock-names = "xtal", "pclk", "baud";
};
&usb0 {