commit | 1810b3bb7bfeaad1fa782235ff0d06c30d6cbf06 | [log] [tgz] |
---|---|---|
author | Michael Hennerich <michael.hennerich@analog.com> | Fri Apr 29 14:17:04 2011 +0200 |
committer | Greg Kroah-Hartman <gregkh@suse.de> | Tue May 03 11:40:03 2011 -0700 |
tree | dd0271982f40e8a62b6f45043db7ffeceb9689d0 | |
parent | 7dd04eb04e0cf6593ff8ee30e9a4a403c1256834 [diff] |
IIO: GYRO: ADXRS450: Don't exit probe, in case the power on default is not met. If the part get's probed twice without hard reset in between, the power on default register read-back can't be met. This shouldn't cause the second probe to fail. So warn but don't exit. Signed-off-by: Michael Hennerich <michael.hennerich@analog.com> Acked-by: Jonathan Cameron <jic23@cam.ac.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>