regulator: Remove MAX8997_REG_BUCK1DVS/MAX8997_REG_BUCK2DVS/MAX8997_REG_BUCK5DVS macros

In current implementation, the original macro implementation assumes the caller
pass the parameter starting from 1 (to match the register names in datasheet).
Thus we have unneeded plus one then minus one operations
when using MAX8997_REG_BUCK1DVS/MAX8997_REG_BUCK2DVS/MAX8997_REG_BUCK5DVS macros.

This patch removes these macros to avoid unneeded plus one then minus one operations
without reducing readability.

Signed-off-by: Axel Lin <axel.lin@gmail.com>
Acked-by: Kyungmin Park <kyungmin.park@samsung.com>
Acked-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
2 files changed