cfg80211: change GO_CONCURRENT to IR_CONCURRENT for STA
The GO_CONCURRENT regulatory definition can be extended to station
interfaces requesting to IR as part of TDLS off-channel operations.
Rename the GO_CONCURRENT flag to IR_CONCURRENT and allow the added
use-case.
Change internal users of GO_CONCURRENT to use the new definition.
Signed-off-by: Arik Nemtsov <arikx.nemtsov@intel.com>
Reviewed-by: Johannes Berg <johannes.berg@intel.com>
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
diff --git a/net/wireless/nl80211.c b/net/wireless/nl80211.c
index 8a33bba..c264eff 100644
--- a/net/wireless/nl80211.c
+++ b/net/wireless/nl80211.c
@@ -639,8 +639,8 @@
if ((chan->flags & IEEE80211_CHAN_INDOOR_ONLY) &&
nla_put_flag(msg, NL80211_FREQUENCY_ATTR_INDOOR_ONLY))
goto nla_put_failure;
- if ((chan->flags & IEEE80211_CHAN_GO_CONCURRENT) &&
- nla_put_flag(msg, NL80211_FREQUENCY_ATTR_GO_CONCURRENT))
+ if ((chan->flags & IEEE80211_CHAN_IR_CONCURRENT) &&
+ nla_put_flag(msg, NL80211_FREQUENCY_ATTR_IR_CONCURRENT))
goto nla_put_failure;
if ((chan->flags & IEEE80211_CHAN_NO_20MHZ) &&
nla_put_flag(msg, NL80211_FREQUENCY_ATTR_NO_20MHZ))